Is my building’s metering ready for a NABERS UK rating?

Free readiness checker

Is my building’s metering ready for a NABERS UK rating?

Before a NABERS UK rating can go ahead, the energy data behind it has to meet the metering and consumption rules. That means a full, continuous 12 months of actual (not estimated) data, meters that are validated where the rules require it, and estimates that stay within 5% of the building’s total emissions. If you are not sure you have that, our free NABERS UK readiness checker shows you where the gaps are before your rating period opens.

At a glance

Free
Best for
NABERS UK rates the in-use energy performance of offices, and CIBSE Certification administers the scheme in the UK. The checker is for building owners, asset managers, facilities teams and assessors who need to know whether the metering and data are rating-ready, particularly in buildings with sub-meters, current transformer (CT) meters or a BMS feeding data to a rating.
You get
You get an overall readiness score and a score for each of the five areas, then a gap report that lists what is missing and which section of the rules it relates to.
What the checker asks

What it covers, area by area.

It is 22 yes, no or not applicable questions in five areas, each tied to the section of the NABERS UK Metering and Consumption Rules it comes from. You enter your name, company and work email first, then choose your building type.
NA
Free checker

NABERS UK metering readiness checker

Supply points and coverage
Have all energy sources been identified on a single-line diagram, are utility meters used in preference to non-utility meters, are non-utility meters cumulative, and have any cloud or BMS-fed meters used for inclusions been reconciled against a parent utility meter?
Utility metering data
Do you have 12 months of continuous, non-estimated data, have estimated bills been corrected using actual cumulative readings, are readings available at least quarterly, and has the data been checked for rollovers, meter changes and faults?
Non-utility metering data
Does the data carry the date, meter ID, k-factor and calculated kWh the rules expect, is there 12 continuous months, and for gas meters is measured pressure and energy density recorded?
Meter validation
Have CT meters been validated by a licensed electrician, do validation records show the ratio, wiring check and sign-off, have gas and remote-reading systems been validated, is the evidence recent enough, and for newer buildings have all non-utility meters been validated rather than a sample?
Estimates and records
Have un-metered end uses been identified and estimated sensibly, do your estimates stay within the 5% limit, and are the records being kept in an audit-ready form?

How to read your result

You get an overall readiness score and a score for each of the five areas, then a gap report that lists what is missing and which section of the rules it relates to. Metering and validation gaps are the ones that take longest to fix, because they can mean site visits, engineer sign-off or changing how a meter is connected, so start there.

An example (illustrative, not a real client)

Imagine a 1990s office with three utility supplies and a handful of CT sub-meters. It answers the checker and scores 64%. Supply points and utility data are mostly ready. The gaps are that two months of electricity are billed on estimates, the CT meters have never been validated, and the single-line diagram does not match what is on site. The action list is practical: get actual readings to replace the estimates, book a licensed electrician to validate the CT meters, and update the diagram before the assessor asks for it.

What the rules ask for

According to the NABERS UK Metering and Consumption Rules, acceptable data covers one complete and continuous year. Estimated utility bills are not acceptable data on their own and need correcting with actual cumulative meter readings, with readings at least quarterly. Acceptable estimates must total no more than 5% of the rating’s overall greenhouse gas emissions, a figure the rules call the potential error, and records have to be kept for seven years from when the rating application was lodged.
CT-metered systems need validating by a licensed electrician or electrical engineer, and validation evidence needs to be within the last ten years. Where a building’s certificate of completion is on or after 1 January 2021 and validation is required, all non-utility metering systems used in the rating must be validated, not just a sample.

Want help getting the metering ready?

If the checker shows metering or validation gaps, we can help. Our energy monitoring kit is a quick way to start collecting interval data from a site, and you can also talk to us about metering, validation and getting a building ready before the rating period opens.
Working on other reporting requirements too? Try our ESOS Phase 4 data readiness checker or our GRESB energy and water data checker. You can also try the UK Net Zero Carbon Buildings Standard readiness checker.
Common questions

Answered.

Can I use estimated utility bills?

Not as they stand. Estimated bills are not acceptable data, but they can be corrected using actual cumulative meter readings, so ask your supplier or read the meter and replace the estimates.

Can I use BMS or cloud meter data?

Often yes, but with conditions. Soft meter data is only acceptable for exclusions, and non-cumulative meters can only be used for inclusions if they reconcile against a parent utility meter and are fully complete. The checker flags both.

Who validates a CT meter?

A licensed electrician or electrical engineer. The record should show the ratio, the wiring check and their sign-off.

See where you stand.

The checker is free and shows you what is in place, what is missing and where to start.
This page is general information, not an assessment or a guarantee of a rating. Always check the current NABERS UK rules and speak to a licensed assessor. Monitor Hut is not affiliated with NABERS or CIBSE Certification.